Reinforced concrete does not break down into clean aggregate. It breaks down into aggregate plus a stubborn second product: bent, twisted, wire-bound rebar that arrives at the magnet in bundles rather than as separate pieces. A Self-Cleaning Electromagnetic Separator sized for loose tramp iron will capture the top bar of that bundle and lose the rest, and every downstream machine pays for the difference. This guide sets out how rebar bundles actually behave in a C&D recycling line, what the magnet has to do about it, and how to design the discharge end so the magnet is not blamed for a chute problem.
A self-cleaning magnetic separator handles rebar bundles when three conditions are met: the magnet face is wider than the conveyor and set as low as the peak burden allows, the cleaning belt is cleated and runs faster than the main belt, and the discharge chute is steep, wide and screened against long bars. Magnet strength alone does not solve bundles — geometry does.
![]()
· ✔ Bundles fail by mechanical interlock and leverage, not by insufficient gauss alone.
· ✔ Size the gap from peak burden depth, not from average tonnage per hour.
· ✔ A cleated cleaning belt running 0.5–1.0 m/s faster than the main belt prevents drop-back.
· ✔ The discharge chute causes more rebar stoppages than the magnet circuit does.
· ✔ Recovered rebar has scrap value that often covers annual magnet running costs.
· ✔ Application: demolition rubble, road planings, precast rejects, and washed recycled aggregate plants.
|
Item |
Typical Specification for C&D Feed |
Function |
|
Magnet type |
Self-cleaning electromagnetic overband, oil-cooled |
Adjustable field, survives shock loading |
|
Magnet face width |
Belt width + 300–400 mm |
Prevents side escape of swinging bars |
|
Working gap |
Peak burden + 50–100 mm (typically 250–350 mm) |
Balances field reach against impact risk |
|
Field at working gap |
≥ 90 mT (rare earth) / ≥ 110 mT (electromagnetic) |
Lifts 15–20 kg bundles |
|
Cleaning belt |
25–40 mm cleats at 300–400 mm pitch |
Carries bundles without slipping |
|
Cleaning belt speed |
Main belt + 0.5 to 1.0 m/s |
Clears the face before re-orientation |
|
Discharge chute |
55–60°, throat ≥ 1.5× longest bar |
Prevents bridging |
|
Bar screen |
600–800 mm spacing ahead of chute |
Converts long-bar jams into clearable stops |
|
Drive |
3–7.5 kW coil + 1.5–3 kW belt |
Site electrical capacity |
|
Recovered scrap |
1–3 t/day on a 150–250 t/h line |
Revenue offset |
![]()